Run Control v0.1.0 (2025-06-11)

Added

  • Add PLC / modbus module. This enables communication between run control and PLC. It can start and stop pressure cycle, set pressure setpoint, start and stop PLC taking high resolution data.

  • Implement autorun. If autorun box is checked and the previous run didn’t end by pressing the “STOP RUN” button, a new run will automatically start.

  • Create a run_info.sbc that matches the RunData SQL table for each run, and populate the event_info.sbc to match the EventData SQL table.

  • Add run exit code and event exit code in SQL tables. Specific definitions to come later.

  • Save run control version number in run info and SQL RunData table.

  • Add active modules in SQL and run info file.

  • Change init script to create a ~/.config/runcontrol/ and save the SMB and SQL tokens there.

  • Add changelog.

  • Add lock file so that only one instance of run control runs at a time.

  • Create a symlink for current run folder in data directory, in addition to the current event folder.

Changed

  • Change piezo file format. Now it has “range”, “offset”, and “waveforms” columns.

  • Fix all status lights. The status are idle, working, active, disabled, or error.

  • Simplify enable boxes in settings window general tab.

  • Main log file is renamed rc.log, and is rotated daily.

Fixed

  • Define fast compress pin as output pin in trigger Arduino code.

  • Switch the trigger and trigger latch pins in NIUSB config, because the pin may be malfunctioning as output.

  • Improve terminating workers and threads when closing run contorl.

Run Control v0.0.2 (2025-05-21)

Added

  • Saving version number of red_caen, nius- rc_ver (VARCHAR(100)): b_6501, and sbc_binary_format.

  • Remove dependencies from dependencies folder. Install instead using pip from github.

  • Added CAEN / GaGe driver install scripts to init.sh. Created new root_init.sh to handle the parts that needs root privileges. The script also prompts for SQL token and saves to a file with proper permission.

  • Add event pressure display in main window.

Changed

  • Use git submodule to handle dependencies that cannot be installed using pip, instead of git subtree.

  • Change the structure of config file. Specifically where PLC and pressure configs are organized.

Fixed

  • Update documentation and bug fixes.

Run Control v0.0.1 (2025-04-25)

First versioned release of run control.